Strand Lighting ShowNet DMX

Your console can connect directly with any Strand Lighting ShowNet Network, transmitting levels to other Strand Lighting Nodes or Strand Dimmer Racks that are part of that Network.

Note:

ShowNet uses Broadcast communications in which IP addresses are not used. Regardless, it is a good idea to know what Subnet you are broadcasting on. See Control Panel - Network.

The ShowNet configuration is setup in the Patch. In the top left hand pane, you can configure the Output Devices by clicking the [+] sign to expose the Output Device options. By default, the DMX ports on the back of your console (USB DMX) are mapped to Outputs 1 through 1024.

Double click on the cell to the right of ShowNet.  From the drop down list, select the number of universes that you wish to send over ShowNet.  Here you can select up to 20 universes (10240 DMX channels).

 

In the ShowNet XDMX Start cell, enter the starting point where this information will appear on the network.  This information is entered as logical network universe numbers, rather than as discrete NetSlots.

XDMX Start

ShowNet NetSlot

XDMX Start

ShowNet NetSlot

XDMX Start

ShowNet NetSlot

XDMX Start

ShowNet NetSlot

1

1

10

4609

19

9217

28

13825

2

513

11

5121

20

9729

29

14337

3

1025

12

5633

21

10241

30

14849

4

1537

13

6145

22

10753

31

15361

5

2049

14

6657

23

11265

32

15873

6

2561

15

7169

24

11777

33

16385

7

3073

16

7681

25

12289

34

16897

8

3585

17

8193

26

12801

35

17409

9

4097

18

8705

27

13313

36

17921

Note:

Where more than one Universe is being sent over ShowNet, the console can be configured to send the data over mutliple XDMX start addresses.   This is done by entering the XDMX start as a comma separated list. The following example sends the first three universes from the Patch over the network:

The XDMX settings then post the data on the Network as follows:

Output Range

XDMX

Start

ShowNet NetSlot

1-512

1

1-512

513-1024

5

2049-2560

1025-1536

7

3073-3584

If you are using SN110 series nodes, their configuration may be set by using Internet Explorer, which can be accessed using the Control Panel.

To configure your ShowNet nodes enter the IP address of the node you want to change:

A web page will appear where you can then change the various parameters:

See Also:

Patch

Pathport